DC-DC Converter AVP-3/Ks and AVP-3/Ksp

Output Power up to 36 Watt
• Isolated
• Triple output
• For pcb mounting (AVP/Ksp) and chasis mounting (AVP/Ks)
• CE marked
• Overtemperature shutdown
• Remote off
• No overshoot of output voltage at switching on
• Short circuit protected
• Overvoltage protection in the output circuit, at the 2. positive voltage
even in case of external supply (OVP)
• Vibration resistant and indifferent to humidity due to encapsulated case
• Ambient temperature: -40°C up to +85°C

 
Vin/V
Vout1/V
Iout1/A
Vout2/V
Iout2/A
Vout3/V
Iout3/A
Type
Order number
min.
max.
9
40
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ks
09 41 62 0112 2
15
36
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ks
09 41 92 0112 5
32
74
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ks
09 41 52 0112 4
66
154
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ks
09 41 72 0112 9
9
40
+5,0
1,2
+15,0
1,0
-15,0
1,0
AVP-3/Ks
09 41 63 0112 1
15
36
+5,0
1,2
+15,0
1,0
-15,0
1,0
AVP-3/Ks
09 41 93 0112 4
32
74
+5,0
1,2
+15,0
1,0
-15,0
1,0
AVP-3/Ks
09 41 53 0112 3
66
154
+5,0
1,2
+15,0
1,0
-15,0
1,0
AVP-3/Ks
09 41 73 0112 8
9
40
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ksp
09 41 62 0172 2
15
36
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ksp
09 41 92 0172 5
32
74
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ksp
09 41 52 0172 4
66
154
+5,0
1,2
+12,0
1,3
-12,0
1,3
AVP-3/Ksp
09 41 72 0172 9
9
40
+5,0
1,2
+15,0
1,3
-15,0
1,0
AVP-3/Ksp
09 41 63 0172 1
15
36
+5,0
1,2
+15,0
1,3
-15,0
1,0
AVP-3/Ksp
09 41 93 0172 4
32
74
+5,0
1,2
+15,0
1,3
-15,0
1,0
AVP-3/Ksp
09 41 53 0172 3
66
154
+5,0
1,2
+15,0
1,3
-15,0
1,0
AVP-3/Ksp
09 41 73 0172 8

back