AER03 - Output power 3 Watt for railway
Autronic, the leading supplier of power supplies for railway technology, has over the years expanded its portfolio of DC/DC converters in the power range from 3W to 350W and recently offers new brick-type solutions according EN 50155.
DC / DC converter AER03, compact power supply for the railway.
The Autronic AER03 series is a new series of railway-approved and isolated 3W DC/DC converters in potted DIP24 package. The brick solutions have been designed specifically for railway applications. The compact power supplies can be used as a highly reliable solution in railway systems, battery-operated devices, gauges and many critical applications in harsh environments for power conversion at the point of load.
The high degree of efficiency of up to 85% facilitates the design-in of the power supply; the EMC according to EN 50121-3-2 is met with small externally designed components. The modules are designed for use in a temperature range of -40°C to 85°C and therefore meet the requirements for temperature class TX. Other features are high I/O isolation with 3000VAC and a reinforced insulation.
The AER03 has some integrated protection functions. As a standard equipment, the DC/DC converter is protected against overcurrent and overvoltage, in addition, the converters are short-circuit proof. EMI filters are compliant with EN 55032 & FCC Part 15 Class A.
The small bricks meet the environmental requirements of shock/vibration according to EN 61373 category 1 class B, dry and damp heat according to EN 60068-2-1, 2, 30 and the EMC standard EN 50121-3-2 for railway vehicles, as well as the railway standard EN 50155. Fire protection tests according to EN 45545-2 have been carried out.
There are 15 versions available for railway voltages of 12/24 (9 ... 36) VDC, 36/48 (18 ... 75) VDC or 72/110 (40 ... 160) VDC, all with accurate output voltage regulation. The single output versions are available with voltages of 5V, 12V and 15V. The AER03 family is complemented by dual-output versions with output voltages of ±12V and ±15V.
Overview key figures AER03:
- Industrial Standard DIP-24 Package
- Wide input range 9-36VDC, 18-75VDC, 40-160VDC
- I/O isolation 3000 VAC with reinforced insulation
- Operating ambient temperature -40°C to +92°C
- No min. load requirement
- Overload and short circuit protection
- Designed-in conducted EMI meets EN 55032/22 Class A & FCC Level A
- Vibration and shock according EN 61373 (Pending)
- Cooling, dry & damp heat test according EN 60068-2-1, 2, 30
- Fire and Smike according EN 45545-2
- Railway EMC standard according EN 50121-3-2
- Railway certified according EN 50155 (IEC60571)
- UL/cUL/IEC/EN 62368-1 (60950-1) safety approval & CE marking
Reach√ RoHs√ material conflict free√
Vin/V min. - max. |
Vout1/V | Iout1/mA | Vout2/V | Iout2/mA | Type | Order number |
---|---|---|---|---|---|---|
Single Output | ||||||
9 - 36 | 5 | 600 | AER03-24S05 | 11751103216 | ||
9 - 36 | 12 | 250 | AER03-24S12 | 11751103221 | ||
9 - 36 | 15 | 200 | AER03-24S15 | 11751103235 | ||
18 - 75 | 5 | 600 | AER03-48S05 | 11751103516 | ||
18 - 75 | 12 | 250 | AER03-48S12 | 11751103521 | ||
18 - 75 | 15 | 200 | AER03-48S15 | 11751103535 | ||
40 - 160 | 5 | 600 | AER03-110S05 | 11751103713 | ||
40 - 160 | 12 | 250 | AER03-110S12 | 11751103727 | ||
40 - 160 | 15 | 200 | AER03-110S15 | 11751103732 | ||
Dual Output | ||||||
9 - 36 | +12 | 125 | -12 | 125 | AER03-24D12 | 11751103249 |
9 - 36 | +15 | 100 | -15 | 100 | AER03-24D15 | 11751103254 |
18 - 75 | +12 | 125 | -12 | 125 | AER03-48D12 | 11751103549 |
18 - 75 | +15 | 100 | -15 | 100 | AER03-48D15 | 11751103554 |
40 - 160 | +12 | 125 | -12 | 125 | AER03-110D12 | 11751103746 |
40 - 160 | +15 | 100 | -15 | 100 | AER03-110D15 | 11751103751 |